Knowledge Base › Selection Error Cases › Oil Temperature Uncontrollable Due to Wrong Thermostatic Valve Selection in Hydraulic Systems

Oil Temperature Uncontrollable Due to Wrong Thermostatic Valve Selection in Hydraulic Systems

E41-697 · Hydraulic Component Selection · Thermostatic Valve Selection · ★★★

Problem Description

The wax-element thermostatic valve did not actuate at 65°C oil temperature, and the oil temperature rose to 85°C.

Root Cause

The wax-element thermostatic valve responded slowly (15 min); the oil temperature had already risen to 65°C within 10 min, and the sensing bulb inserted in the tank caused additional lag.

Corrective Solution

① Install the sensing bulb in the main oil line near the cooler inlet
② Use an electrically controlled thermostatic valve (PT100 + PLC)
③ Install a manual shutoff valve in the bypass circuit

Checklist

Reference

FT_Hydraulic & Pneumatic Design