E41-999 · Hydraulic Component Selection · Hydraulic Oil Selection · ★★★
One system used ISO VG46; at low-temperature startup the viscosity was too high, causing pump suction noise, wear, and low efficiency.
First, viscosity ν changes with temperature; at low temperature ν rises sharply, causing pump suction resistance and cavitation. Second, at high temperature ν becomes small, increasing leakage and lowering volumetric efficiency. Root cause: wrong viscosity.
① Select oil viscosity by operating temperature (VG46 for normal temperature, VG68 for high temperature, VG32 for low temperature)
② Use a high viscosity index VI (≥95) to reduce temperature variation
③ Provide heating/cooling to control temperature at 40–60°C
④ Verify ν is within the pump allowable range
⑤ Do not use a single viscosity over a wide temperature range
⑥ Periodically check viscosity
⑦ If suction starvation occurs, check viscosity immediately