E41-1000 · Hydraulic Component Selection · Hydraulic Heat Dissipation · ★★★★
One system had no cooling; the oil temperature rose to 85°C, seals aged and leaked, efficiency dropped, and the unit shut down.
First, system heat generation H=Δp·Q·(1-η); with no heat dissipation the oil temperature rises; 85°C exceeds the 60°C allowable. Second, high temperature thins the oil film, ages seals and causes leakage, and lowers efficiency. Root cause: insufficient heat dissipation.
① Control oil temperature at 40–60°C; add a cooler (air/water) when exceeded
② Verify the balance between heat generation H and heat dissipation
③ Tank volume ≥3 times pump flow to aid heat dissipation
④ Use high-temperature seals / oil
⑤ Do not run hot without cooling
⑥ Install a temperature switch
⑦ If overheated, check heat dissipation immediately
FT_Hydraulic & Pneumatic Design