E41-1001 · Hydraulic Component Selection · Hydraulic Contamination · ★★★★
One return filter element was clogged; pump suction vacuum was high, cavitation noise occurred, parts failed, and the unit stopped.
First, a clogged filter raises suction resistance and pump inlet vacuum exceeds NPSH → cavitation. Second, cavitation damages pump parts and causes noise. Root cause: clogged filter.
① Replace filter elements periodically and install a clogging differential pressure alarm
② Suction filter element precision ≤100 μm with large flow capacity
③ Control oil cleanliness to ISO 4406 ≤19/16
④ Pump inlet vacuum ≤0.02 MPa
⑤ Do not run with a clogged filter
⑥ Install a differential pressure switch
⑦ If noisy, check the filter immediately
FT_Hydraulic & Pneumatic Design