E41-1002 · Hydraulic Component Selection · Water-Glycol Cylinder · ★★★
In one water-glycol system, the plain steel piston rod rusted, seals were scratched and leaked, and it was replaced monthly.
First, although water-glycol is fire-resistant, its water content corrodes plain steel; rust scratches seals and causes leakage. Second, replaced monthly. Root cause: wrong rod material.
① Rods for water-glycol service must be stainless steel / hard chrome (water-erosion resistant)
② Use water-resistant seals (NBR / polyurethane)
③ Do not use plain steel rods
④ Check for rust periodically
⑤ Apply anti-rust treatment to the system
⑥ Use water-proof seals
⑦ If leaking, check the rod immediately
FT_Hydraulic & Pneumatic Design