E41-1004 · Hydraulic Component Selection · Hydraulic Pump · ★★★★

Problem Description

One pump had a long, narrow suction line; cavitation noise, part damage, and low efficiency resulted.

Root Cause

First, a long narrow suction line raises resistance and inlet vacuum exceeds NPSH → cavitation. Second, cavitation damages parts and causes noise. Root cause: insufficient suction.

Corrective Solution

① Suction pipe diameter ≥1.5 times the pump port, short and straight
② Inlet vacuum ≤0.02 MPa, with NPSH margin
③ Tank liquid level above the pump
④ Do not use long narrow suction lines
⑤ Check for cavitation noise
⑥ Use suitable oil viscosity
⑦ If damaged, check suction immediately