E41-1005 · Hydraulic Component Selection · Accumulator · ★★★
One accumulator had too small a volume; during pressure holding the makeup was insufficient, pressure dropped, and parts were scrapped.
First, accumulator volume V must be calculated from the pressure-holding oil makeup; a small V gives insufficient makeup and pressure drop. Second, scrapped. Root cause: small volume.
① Calculate accumulator V from pressure-holding makeup / pulsation absorption volume and leave margin
② Precharge pressure p0=0.8–0.9 times the lower working limit
③ Select bladder / piston type according to the medium
④ Verify the gas law pV^n
⑤ Do not use a small volume for pressure holding
⑥ Check gas pressure periodically
⑦ If pressure drops, check V immediately
FT_Hydraulic & Pneumatic Design