E41-1009 · Hydraulic Component Selection · Electro-Hydraulic Servo · ★★★★
One servo application used a proportional valve instead of a servo valve; frequency response was low, tracking poor, oscillation occurred, and it was scrapped.
First, proportional valve frequency response ≈10 Hz while servo valves are ≥50 Hz; low response causes tracking lag and overshoot. Second, oscillation and scrapping. Root cause: wrong valve type.
① Servo applications require servo valves / high-frequency proportional valves (frequency response ≥50 Hz)
② Select valve frequency response ≥3 times the closed-loop bandwidth
③ Pair high-response valves with high-cleanliness oil
④ Do not use a proportional valve in place of a servo valve
⑤ Verify the lag
⑥ Provide feedback
⑦ If oscillating, check the valve immediately
FT_Hydraulic & Pneumatic Design