Problem Description

One hydraulic lock had internal leakage; cylinder pressure holding dropped, the workpiece fell, and it was a hazard.

Root Cause

First, internal lock leakage drains the pressure-holding chamber and causes pressure drop. Second, falling is a hazard. Root cause: lock leakage.

Corrective Solution

① Hydraulic locks must have low internal leakage (double-ball locks)
② Use zero-leakage types for pressure holding
③ Lap the valve seat seal
④ Do not use internally leaking locks for pressure holding
⑤ Check for leakage periodically
⑥ Add a mechanical lock for double protection
⑦ If pressure drops, check the lock immediately