Wrong Pump Rotation Direction (Reverse Rotation)

E41-1011 · Hydraulic Component Selection · Hydraulic Pump · ★★

Problem Description

One pump rotated in reverse; it did not deliver oil, burned out, and was scrapped.

Root Cause

First, pump rotation must match the marked direction; reversed it does not deliver oil and burns from dry friction. Second, scrapped. Root cause: wrong rotation direction.

Corrective Solution

① Pump rotation must match the marked direction (arrow)
② Verify motor rotation before wiring
③ Jog once to check rotation direction
④ Do not reverse-connect
⑤ Install phase sequence protection
⑥ Check the oil level
⑦ If burned, check rotation direction immediately

Checklist