Knowledge Base › Selection Error Cases › Valve Sticking Due to Contaminated Oil (Particles)

Valve Sticking Due to Contaminated Oil (Particles)

E41-1012 · Hydraulic Component Selection · Hydraulic Contamination · ★★★

Problem Description

One system had poor oil cleanliness; the valve spool stuck, action was erratic, and it was scrapped.

Root Cause

First, particles entering the valve stick the spool and cause erratic action. Second, scrapped. Root cause: contamination.

Corrective Solution

① Control oil cleanliness to ISO 4406 ≤19/16 (servo ≤13/10)
② Return-line filtration + periodic oil change
③ Add a fine filter upstream of the valve
④ Do not use contaminated oil
⑤ Check cleanliness periodically
⑥ Flush the system
⑦ If stuck, check contamination immediately