Problem Description

At a cylinder speed of 1 m/s, the end-of-stroke impact was loud.

Root Cause

The cushioning needle valve was fully open with no throttling; the impact kinetic energy of 1 J exceeded the cushioning plunger absorption capacity of 0.5 J by 100%.

Corrective Solution

① Start cushioning needle valve adjustment from 1/4 turn and increase gradually
② Cylinder speed ≤0.5 m/s
③ Add external hydraulic shock absorbers