Knowledge Base › Selection Error Cases › Pressure Loss Due to Undersized Pneumatic Tubing

Pressure Loss Due to Undersized Pneumatic Tubing

E41-703 · Pneumatic Component Selection · Air Tubing Pressure Loss · ★★★

Problem Description

At the compressor outlet 0.8 MPa, but only 0.45 MPa at the equipment inlet.

Root Cause

The Φ8 tube was 50 m long; flow velocity 146.5 m/s (recommended ≤15 m/s), causing large pressure drop.

Corrective Solution

① Size tubing inner diameter so flow velocity ≤15 m/s
② Keep tubing length short and add intermediate air receivers
③ Match fitting inner diameter to tubing to avoid necking

Checklist

Reference

FT_Hydraulic & Pneumatic Design