E41-703 · Pneumatic Component Selection · Air Tubing Pressure Loss · ★★★
At the compressor outlet 0.8 MPa, but only 0.45 MPa at the equipment inlet.
The Φ8 tube was 50 m long; flow velocity 146.5 m/s (recommended ≤15 m/s), causing large pressure drop.
① Size tubing inner diameter so flow velocity ≤15 m/s
② Keep tubing length short and add intermediate air receivers
③ Match fitting inner diameter to tubing to avoid necking
FT_Hydraulic & Pneumatic Design