Knowledge Base › Selection Error Cases › Output Power Drop Due to Excessive Exhaust Back Pressure in Pneumatic Motor

Output Power Drop Due to Excessive Exhaust Back Pressure in Pneumatic Motor

E41-707 · Pneumatic Component Selection · Pneumatic Motor Exhaust · ★★★

Problem Description

The pneumatic motor output power dropped from 2 kW to 1.2 kW, and speed from 3000 to 2000 rpm.

Root Cause

The exhaust pipe was 5 m long, Φ6 mm; exhaust back pressure 0.2 MPa; the motor effective pressure differential dropped from 0.55 to 0.4 MPa.

Corrective Solution

① Exhaust back pressure ≤0.05 MPa
② Exhaust pipe port size ≥ inlet port size
③ Select a low-back-pressure muffler ≤0.02 MPa

Checklist

Reference

FT_Hydraulic & Pneumatic Design