Problem Description

The Φ20 mm suction cup dropped the workpiece while lifting a 5 kg steel plate.

Root Cause

The Φ20 cup suction force 25.1 N< the 49 N load; safety factor 2 was not included; a Φ40 mm cup is actually required.

Corrective Solution

① Cup diameter calculated from suction force including safety factor 2
② Consider handling acceleration
③ Rough surfaces affect sealing