E41-709 · Pneumatic Component Selection · Pneumatic System Condensate · ★★★★
In winter, directional valves and cylinders stuck frequently and surfaces rusted.
The refrigerated dryer was off and not running; moisture in the compressed air condensed in the piping and entered pneumatic components.
① Run the refrigerated dryer normally (pressure dew point ≤10°C)
② Install drain valves at low points in piping
③ Timed automatic draining of the air receiver