Component Rust Due to Unremoved Condensate in Pneumatic System

E41-709 · Pneumatic Component Selection · Pneumatic System Condensate · ★★★★

Problem Description

In winter, directional valves and cylinders stuck frequently and surfaces rusted.

Root Cause

The refrigerated dryer was off and not running; moisture in the compressed air condensed in the piping and entered pneumatic components.

Corrective Solution

① Run the refrigerated dryer normally (pressure dew point ≤10°C)
② Install drain valves at low points in piping
③ Timed automatic draining of the air receiver

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »