E41-712 · Pneumatic Component Selection · Pneumatic Sequence Error · ★★★★

Problem Description

Cylinder B extended before cylinder A clamped, and the drill bit broke.

Root Cause

Cylinder A's magnetic switch was mounted too early (triggered 20 mm before reaching position); cylinder B mis-actuated before A was fully clamped.

Corrective Solution

① Mount magnetic switches at the fully stroked piston position
② Set a 0.1–0.3 s delay before triggering the next cylinder
③ Set interlock logic

Checklist

Reference