Knowledge Base › Selection Error Cases › Injury Accident Due to Aged Pneumatic Hose Burst

Injury Accident Due to Aged Pneumatic Hose Burst

E41-711 · Pneumatic Component Selection · Air Hose Burst · ★★★★★

Problem Description

The PU tube burst after 3 years of use; high-pressure air blew up iron chips and injured a person.

Root Cause

UV aging embrittled the PU tube; microcracks formed under pressure cycling and propagated to burst (standard life 2 years).

Corrective Solution

① Use air tubing within its service life (PU tube ≤2 years)
② Avoid direct UV exposure
③ Keep air tubing ≥300 mm from heat sources
④ Inspect every six months

Checklist

Reference

FT_Hydraulic & Pneumatic Design