Problem Description

Air supply pressure fluctuated between 0.5 and 0.7 MPa, and cylinder speeds were inconsistent.

Root Cause

The 0.5 m³ air receiver was too small; the compressor load/unload differential of ±0.1 MPa caused a 30 s periodic pressure fluctuation.

Corrective Solution

① Air receiver volume ≥1/5 of compressor displacement
② Add a pressure regulator with accuracy ±0.01 MPa
③ Stagger use of air-consuming equipment