Knowledge Base › Selection Error Cases › Condensate Accumulation Due to Improper Pneumatic Pipe Layout

Condensate Accumulation Due to Improper Pneumatic Pipe Layout

E41-715 · Pneumatic Component Selection · Air Pipe Condensate · ★★★

Problem Description

In winter, downstream pneumatic components accumulated large amounts of water and rusted.

Root Cause

The main pipe was laid horizontally without slope; condensate accumulated at low points and was carried into equipment by airflow.

Corrective Solution

① Give the main pipe a 1:100 drainage slope toward the end
② Install automatic drain valves at the lowest points
③ Take branch lines from the top of the main pipe

Checklist

Reference

FT_Hydraulic & Pneumatic Design