E41-915 · Pneumatic Component Selection · Vacuum Handling Suction Cup · ★★★★
One vacuum handling cup (Δp=60 kPa) had small area; suction F=Δp·A=60e3·0.002=120 N< workpiece weight 150 N×safety 2=300 N; the workpiece dropped.
First, suction F=Δp·A·n; with A=20 cm², Δp=60 kPa, n=1, F=120 N. Second, required F≥workpiece weight×safety (2); workpiece weight 150 N → requires 300 N; 120 N insufficient, so it dropped. Third, dropped parts damage production. Root cause: small cup area.
① Suction F=Δp·A·n must be ≥workpiece weight×safety factor (vertical ≥4, horizontal ≥2)
② If A is insufficient, enlarge cups / increase number n
③ Take Δp at the vacuum pump limit (typically 60–80 kPa)
④ Verify workpiece weight/mu; for irregular shapes use distributed multiple cups
⑤ Do not lift heavy objects with a single small-area cup
⑥ Provide vacuum holding + vacuum break valve
⑦ If parts drop, check suction immediately
FT_Hydraulic & Pneumatic Design