E41-916 · Pneumatic Component Selection · Vacuum Generator · ★★★
One vacuum generator had small flow; evacuation was slow >1 s, the cycle dropped, and occasionally suction was unstable and parts dropped.
First, generator exhaust flow Q must be ≥cup volume/response time; small Q makes evacuation t>1 s. Second, long t drops the cycle, and vacuum cannot hold under leakage. Third, parts drop. Root cause: small generator flow.
① Select generator flow Q from cup volume V and response t (Q≥V/t)
② Use large-flow generators or a vacuum pump for multiple cups
③ Verify time to reach vacuum ≤0.5 s
④ Make tubing short and large to reduce volume
⑤ Install a vacuum switch to confirm stable suction before motion
⑥ Do not pair small flow with large volume
⑦ If slow/parts drop, check flow immediately
FT_Hydraulic & Pneumatic Design