E41-919 · Pneumatic Component Selection · Long-Distance Air Tube · ★★★
One 30 m air tube had 4 mm inner diameter; end pressure dropped 40%, and the cylinder had no force.
First, line pressure drop Δp∝L/d⁵ (laminar); d=4 mm is thin and L=30 m makes Δp large. Second, end p=0.5·0.6=0.3 MPa, halving output. Third, cylinder slow and weak. Root cause: small + long tube.
① Size long-distance supply tube by flow (d≥√(128·μ·L·Q/(π·Δp))); do not make it too thin
② Use large main lines (≥8 mm); branches to local valve islands
③ Control pressure drop ≤10% of supply
④ Add an air receiver for buffering
⑤ Do not use thin tubes over long distances
⑥ Provide end pressure regulation
⑦ If weak, check tube diameter immediately
FT_Hydraulic & Pneumatic Design