E41-920 · Pneumatic Component Selection · Winter Air Supply · ★★★
One northern winter the air supply dew point was only +5°C; piping froze and blocked, valves stuck, and the whole line stopped.
First, dew point must be below the minimum ambient temperature (winter -20°C); dew point +5°C leaves liquid water in the pipe that freezes. Second, ice blockage makes Δp surge and valves stick. Third, the whole line stops. Root cause: insufficient drying.
① Dew point must be ≥10°C below minimum ambient (winter -20°C requires dew point ≤-30°C)
② Provide a refrigerated dryer (dew point +3°C) or adsorption dryer (≤-40°C)
③ Add insulation / heat tracing to piping for freeze protection
④ Periodically drain low-point drain valves
⑤ Do not winter with a high dew point
⑥ Add dew point monitoring
⑦ If freezing, check the dryer immediately
FT_Hydraulic & Pneumatic Design