Problem Description

One vacuum system used a -0.1 MPa ordinary pressure gauge in place of a vacuum gauge; readings were inaccurate, suction hard to judge, and parts occasionally dropped.

Root Cause

First, vacuum level requires a vacuum gauge (range 0 to -101 kPa absolute); ordinary pressure gauges cannot read negative pressure accurately. Second, fuzzy readings make it hard for operators to judge stable suction, occasionally dropping. Third, scrapped. Root cause: wrong gauge type.

Corrective Solution

① Use vacuum gauges (absolute/negative-pressure specific) in vacuum systems
② Range covers operating vacuum level
③ Install a vacuum switch + digital display
④ Do not use ordinary pressure gauges for vacuum
⑤ Calibrate periodically
⑥ Confirm stable suction before motion
⑦ If dropping, check the gauge immediately