E41-934 · Pneumatic Component Selection · Cantilever Cylinder · ★★★
One cantilever-mounted cylinder's trunnion saw bending; the trunnion cracked, the cylinder fell, and equipment was damaged.
First, the trunnion should see pure tension/compression; cantilever loads the trunnion with bending moment M=F·L. Second, M exceeds trunnion bending strength → crack. Third, cylinder falls. Root cause: wrong mounting load.
① Trunnion mounting must allow the pin to pivot freely, taking only tension/compression; no cantilever bending
② Add external guide rails/supports to carry cantilever loads
③ Verify trunnion bending moment ≤ bending strength
④ Use rod-end bearings / rose joints to compensate angular misalignment
⑤ Do not load trunnions in bending
⑥ Check that installation adds no bending
⑦ If cracked, check loads immediately
FT_Hydraulic & Pneumatic Design