Problem Description

One air supply had only a regulator, no filter; wet air at pressure fed the system; valves stuck, cylinders rusted, and faults were frequent.

Root Cause

First, the FRL (filter+regulator) must remove water; without filtration water and oil enter the system. Second, wet air causes valve sticking, cylinder rust, and more faults. Third, unstable pressure causes output fluctuation. Root cause: missing filtration.

Corrective Solution

① Air supply must have filtration + regulation (add drying in wet environments)
② Auto/manual drain for the filter
③ Filter element precision ≤40 μm, replaced periodically
④ With much water add fine filtration + dryer
⑤ Do not regulate without filtration
⑥ Drain the air receiver upstream of the compressor
⑦ If faults are frequent, check water immediately