E41-730 · Seal Component Selection · Combination Seal Stick-Slip · ★★★★
A hydraulic cylinder (working pressure 21 MPa, speed 0.01 m/s) used a step seal + Glyd ring combination; stick-slip appeared at low speed.
The step seal (stepped ring) + Glyd ring (PTFE + bronze composite) were used for high-pressure service, but at low speed (<0.05 m/s) the friction coefficient is high (static μ_s=0.08, kinetic μ_k=0.04), causing stick-slip. The step seal's stepped lip seats tightly against the bore wall at rest (ensuring zero leakage); at start it must overcome static friction (about 500 N); once moving, friction drops to 250 N, and the 200 N force difference accelerates the piston (a=ΔF/m=200/50=4 m/s²); speed spikes instantly → bore squeeze on the seal increases → friction rises → decelerate → stop → restart. Stick-slip frequency about 1 Hz, obvious at very low speed.
① Verify seal selection against sealing conditions (pressure/temperature/media/speed)
② Confirm material and hardness meet requirements
③ Control journal roughness and runout to prevent eccentric wear
④ Install correctly (lubricate the lip, prevent reverse installation)
⑤ Periodically inspect and replace on schedule
FT_Seal Spring Design