Knowledge Base › Selection Error Cases › Low-Temperature Seal Hardening Leak (LNG Pump)

Low-Temperature Seal Hardening Leak (LNG Pump)

E41-896 · Seal Component Selection · LNG Cryogenic Pump · ★★★★

Problem Description

One LNG pump (-162°C) used a plain NBR ring; it glass-transitioned and hardened at low temperature, the lip cracked and leaked, posing a fire/explosion hazard.

Root Cause

First, NBR glass transition Tg≈-20°C; -162°C is far below Tg, elastic modulus E rises 10×, hard as stone. Second, the hard ring cannot conform to the shaft surface; gap >0.3 mm → leak. Third, LNG fire/explosion hazard. Root cause: insufficient low-temperature resistance.

Corrective Solution

① For below -40°C use FFKM (rated -40 to -60°C) or special FKM
② Leave margin to minimum temperature on Tg (Tg < minimum temp by 20°C)
③ In LNG service, metal seals (Inconel/Cu) are more reliable
④ Do not use NBR/plain rubber in cryogenic service
⑤ Insulate to prevent condensation
⑥ Periodically check hardness and cracks
⑦ If leaking, check material temperature immediately

Checklist

Reference

FT_Seal Spring Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »