Insufficient Seal Compression Causing Leak (Low-Pressure Valve)

E41-898 · Seal Component Selection · Low-Pressure Water Valve · ★★

Problem Description

One 0.3 MPa water valve O-ring groove depth was wrong, giving only 5% compression; slight leak became a stream, pooling water on the floor.

Root Cause

First, compression δ=(d2-h)/d2=5%< the static minimum 15%; contact stress σ_c<0.3 MPa< water pressure. Second, the medium pushes the ring open into a gap and leaks. Third, although pressure is low, pooling damages the environment. Root cause: insufficient compression.

Corrective Solution

① Static seal compression ≥15% (dynamic ≥10%)
② Back-calculate groove depth h=d2(1-δ) from wire d2
③ Even at low pressure σ_c >1.2× pressure
④ Measure groove depth before assembly
⑤ Do not use δ<15% for static seals
⑥ If slight leakage, check compression immediately
⑦ Standardize groove dimensions

Checklist

Reference

FT_Seal Spring Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL