Knowledge Base › Selection Error Cases › Over-Compression Permanent Set (High-Pressure Static Seal)

Over-Compression Permanent Set (High-Pressure Static Seal)

E41-899 · Seal Component Selection · High-Pressure Vessel Flange · ★★★

Problem Description

One high-pressure vessel (40 MPa) used O-ring compression of 40%; the ring flattened with permanent set, and lost sealing on reassembly, leaking.

Root Cause

First, δ=40% far exceeds the static maximum 25%; rubber molecular chains slip irreversibly, ε_c>30%. Second, after unloading the ring does not rebound and the cross-section is flat; on reinstall the gap > rebound → leak. Third, high-pressure leakage hazard. Root cause: over-compression.

Corrective Solution

① Static seal compression ≤25% (high pressure take 15–20%)
② Add backup rings at high pressure to prevent extrusion and limit compression
③ Select low-ε_c material (FKM)
④ Design groove depth to the δ upper limit
⑤ Do not use δ>25%
⑥ Periodically check for flat cross-section
⑦ Check rebound on disassembly

Checklist

Reference

FT_Seal Spring Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »