Knowledge Base › Selection Error Cases › Vacuum Flange Leak (Vacuum Chamber)

Vacuum Flange Leak (Vacuum Chamber)

E41-903 · Seal Component Selection · Vacuum Coating Chamber · ★★★

Problem Description

One vacuum chamber flange used a plain rubber gasket; after bake-out the leak rate exceeded and ultimate vacuum was not met.

Root Cause

First, plain rubber has high outgassing; after bake-out the leak rate exceeds the chamber allowance. Second, uneven flange pressure causes local gap leakage. Third, poor coating quality. Root cause: non-vacuum gasket + uneven torque.

Corrective Solution

① Vacuum flanges use OFHC copper gaskets / vacuum-grade FKM with low outgassing
② Tighten bolts diagonally with even torque for uniform pressure
③ Bake out before assembly
④ For high vacuum use metal gaskets (knife-edge flanges)
⑤ Do not use plain rubber in vacuum
⑥ Leak-test periodically
⑦ If vacuum is not met, check the flange

Checklist

Reference

FT_Seal Spring Design