E42-052 · Insufficient Stiffness · Open-Back Press J23-80 · ★★
Uneven burrs on the stampings, dynamic bottom dead center drift 0.12mm
[Column Tensile Deformation] A nominal force of 800kN is carried by two columns at 400kN each. With a column section of 80×120, area A=9600mm² and E=2.1e5MPa, the strain is ε=F/(EA)=400000/(2.1e5×9600)=0.000199 and the elongation ΔL=ε×L=0.000199×600=0.12mm.
[Bottom Dead Center Drift] The elastic elongation of the columns gives 0.12mm of ram descent clearance, so the die closing height fluctuates and produces burrs.
[Design Omission] Column tensile stiffness was not calculated and no pre-tensioned tie rod was fitted for compensation, giving a scrap rate of 7%.
1) Calculate the column tensile stiffness by finite element and add pre-tensioned tie rods;
2) Thicken the section to 100×140 to raise the stiffness;
3) Add a linear scale at the ram bottom dead center for real-time compensation;
4) Monitor the closing height dynamically and alarm on deviation;
5) Grind the die cutting edge regularly to keep it sharp;
6) Grade the stamping speed by material;
7) Inspect the burr of the first article in full;
8) Include column stiffness in press acceptance.
JB/T 1829-2014 Forging Presses — General Technical Conditions