E42-053 · Insufficient Stiffness · Floor Boring Machine T6113 · ★★★
Coaxiality of the coaxial bore group 0.15mm (allowable 0.03), the boring bar droops
[Ram Deflection] The ram section is 140×180 with an overhang L=900mm and I=140×180³/12=6.8e7mm⁴. The cutting force F=1800N gives a deflection δ=FL³/(3EI)=1800×900³/(3×1.1e5×6.8e7)=0.057mm.
[Loss of Coaxiality] The front and rear coaxial bores are machined to the same datum, but the ram droop offsets the rear bore by 0.057mm, giving a cumulative coaxiality of 0.11mm, nearly 4 times out of tolerance.
[Design Omission] The ram had no hydraulic support and no deflection compensation.
1) Add a hydraulic auxiliary support that follows the ram;
2) Calculate the overhang deflection by finite element to ≤0.02mm;
3) Machine the coaxial bores in a single setup;
4) Add an intermediate guide sleeve to the boring bar;
5) Measure and calibrate the cutting force;
6) Inspect coaxiality on a three-coordinate measuring machine for every part;
7) Fit a counterweight balance on the spindle head;
8) Make ram deflection a mandatory inspection item.
GB/T 5289.1-2008 Boring Machines — Inspection of Accuracy