E42-254 · Stiffness Insufficient · XK2730 CNC Gantry Mill · ★★

Problem Description

Table center became saddle-shaped after machining; flatness 0.07 mm (allow 0.02); ends high, middle low.

Root Cause

[Mid-span deflection] table 3000 mm long, wall only 40 mm; under uniform load q, mid-span deflection δ=0.06 mm. [Sag transfer] tool follows table sag, depth gradually increases, cutting 0.06 mm extra at part center. [Design omission] wall safety factor 1.3 (should ≥2.2); no stiffeners.

Corrective Solution

1. Increase table wall from 40 to 60 mm.\n2. Add longitudinal stiffeners underneath, spacing ≤500 mm.\n3. Leave 0.3 mm stock on table top for finish grinding.\n4. Use multiple supports to reduce mid-span load.\n5. FEA verify mid-span deflection ≤0.02 mm.\n6. Finish stock removed in multiple passes.\n7. Inspect flatness full-stroke per batch.\n8. Level support feet uniformly.

Checklist

Reference

JB/T 3028-1993

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »