E42-255 · Stiffness Insufficient · TPX6111B Horizontal Boring Machine · ★★

Problem Description

Slide repeat positioning accuracy 0.03 mm (allow 0.01); two parts machined in same program differ 0.02 mm.

Root Cause

[Poor guide conformity] guide scraped only 4 spots/25×25, contact ratio 40% (should ≥70%); uneven oil film. [Repeat drift] slide contact stiffness varies by position; repeat positioning error 0.03 mm. [Design omission] no guide preload; scraping below spec.

Corrective Solution

1. Scrape guides to ≥10 spots/25×25, contact ratio 80%.\n2. Preload slide to eliminate clearance.\n3. Plastic-lined guide thickness uniform 0.5 mm.\n4. Re-scrape every 500 h.\n5. Add full closed-loop optical scale to positioning.\n6. Switch lubrication to metered centralized supply.\n7. Inspect repeat positioning accuracy each shift.\n8. Guide guards to prevent chip scoring.

Checklist

Reference

GB/T 17421.2-2016

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »