Floor Boring Machine Boring Bar Long Overhang Causing Hole Taper

E42-332 · Stiffness Insufficient · Floor Boring Machine Boring Bar · ★★

Problem Description

Floor boring machine bar (Φ125×1500) boring taper 0.05 mm / full length; 2 units repaired monthly

Root Cause

[Bar deflection] overhang 1500 mm; deflection δ=0.04 mm; bore diameter gradually changes.
[Taper] taper 0.05 mm out of tolerance.
[Design omission] no rear support; bar diameter small; safety factor only 1.2.

Corrective Solution

1) Add rear support sleeve guide;
2) Increase bar diameter to Φ160;
3) Limit overhang ≤10d;
4) Rough/finish separate;
5) Measure taper per batch;
6) Add guide column;
7) Limit cutting force;
8) Periodic inspection.

Checklist

Reference

JB/T 2254-2015