Knowledge Base › Structural Design Error Case Study › CMM Articulated Arm Self-Weight Deflection Causing Repeat Error

CMM Articulated Arm Self-Weight Deflection Causing Repeat Error

E42-333 · Stiffness Insufficient · CMM Articulated Arm · ★★

Problem Description

CMM articulated arm (carbon fiber, length 800) self-weight deflection 0.02 mm; large repeat error; 3 units calibrated monthly

Root Cause

[Arm deflection] overhang 800 mm; self-weight deflection δ=0.02 mm; probe point offset.
[Error] repeat 0.02 exceeds allow 0.005.
[Design omission] no gravity compensation; small section; safety factor only 1.3.

Corrective Solution

1) Enlarge section or add ribs to carbon tube;
2) Gravity compensation algorithm;
3) Limit overhang working range;
4) Lightweight balancing;
5) Calibrate each shift;
6) Temperature compensation;
7) Limit added load;
8) Periodic calibration.

Checklist

Reference

GB/T 16857.2-2017