Problem Description

XK2120 gantry mill crossrail (span 3200 mm); at 2000 mm milling width deflection δ=0.18 mm exceeds allow 0.05; workpiece flatness 0.15 mm out of tolerance; 3 units repaired monthly

Root Cause

[Deflection] crossrail section inertia I=2.1×10⁸ mm⁴ insufficient; estimated δ≈0.18 mm per δ=5qL⁴/(384EI).
[Out of tolerance] cutter sinks with crossrail; machined surface becomes concave at center.
[Design omission] no double-wall box section; no prestressed tie rods; safety factor only 1.3 (should ≥2.5).

Corrective Solution

1) Change crossrail to double-wall box, I≥4×10⁸ mm⁴;
2) Add two prestressed tie rods and pre-tighten;
3) FEA verify deflection ≤0.05;
4) Add longitudinal ribs inside crossrail;
5) CMM-measure deflection per batch;
6) Counterweight to compensate sag;
7) Limit feed speed;
8) Periodic re-measurement.

Checklist

Reference

GB/T 16462-2007