E42-359 · Stiffness Insufficient · Bulk Carrier Hold Deck · ★★
Bulk carrier hold deck (plate 14 mm); cargo-loading localized sag δ=12 mm exceeds allow 5 mm; strength reduced; 1 repair monthly
[Sag] deck plate 14 mm, large span; estimated δ≈12 mm per δ=5qL⁴/(384EI).
[Weakening] stress concentration at sag.
[Design omission] plate thickness low; no longitudinal stiffeners; safety factor 1.4.
1) Thicken deck to 18 mm;
2) Tighten longitudinal stiffener spacing;
3) FEA local strength check;
4) Add local reinforcement plates;
5) Measure flatness per hold;
6) Distribute cargo uniformly;
7) Limit stacking weight;
8) Periodic thickness measurement.
GB/T 9943-2017