E42-502 · Insufficient Stiffness · Horizontal Machining Center (HMC630) · ★★
Table diameter 630mm; under 800kg load the slewing bearing sinks 0.06mm; indexing repeatability ±0.02 exceeds the 0.01 allowance; 3 parts scrapped per month
[Bearing Settlement] Axial load F=12kN, bearing stiffness k=200N/μm; settlement δ=F/k=0.06mm.
[Low Stiffness] Large bearing span, thin housing wall.
[Design Omission] Bearing stiffness not verified, housing not stiffened; safety factor 1.4 (should be ≥2.0).
1) Change slewing bearing to crossed roller;
2) Add annular ribs to housing;
3) Raise wall thickness to 25mm;
4) Measure settlement each shift;
5) Limit load to ≤600kg;
6) Add linear encoder feedback;
7) Preload the bearing;
8) Periodically recheck indexing.
GB/T 23567.1-2009