E42-503 · Insufficient Stiffness · Four-Column Hydraulic Press (2000t) · ★★
Ram width 2000mm; eccentric load causes 0.3mm deflection, exceeding the 0.1 allowance; pressed part thickness variation 0.25mm; 5 parts scrapped per month
[Ram Deflection] Eccentricity e=300mm, bending moment M=Fe; δ=Me/(EI)=0.3mm.
[Insufficient Stiffness] Thin ram section, large guide slenderness ratio.
[Design Omission] Eccentric deflection not verified, no load-equalizing structure; safety factor 1.3 (should be ≥2.0).
1) Thicken ram to 180mm;
2) Provide multi-cylinder load equalization;
3) Lengthen guide;
4) Measure deflection each shift;
5) Limit eccentricity to ≤150mm;
6) Add displacement feedback;
7) Preload the guideways;
8) Periodically recheck thickness.
GB/T 10923-2009