Injection Moulding Clamping Frequency Matches the Machine Natural Frequency and Causes Flash

E42-054 · Vibration & Resonance · Injection Moulding Machine HTF250 · ★★

Problem Symptom

The machine body resonates during clamping and the moulding flash is 0.3mm thick

Root Cause

[Clamping Impact Frequency] With a clamping speed of 0.5m/s and a platen mass of 2.5t, the impact half period is T≈0.02s, giving f≈25Hz; the machine body natural frequency f_n≈26Hz is very close.
[Resonance Amplification] A frequency ratio of 0.96 lands on the resonance peak and the amplitude is amplified Q≈8 times, so the 0.3mm platen relative movement produces flash.
[Design Omission] No modal analysis was done and the clamping circuit had no throttle buffering, giving a flash scrap rate of 12%.

Correct Solution

1) Add throttle buffering to the clamping circuit to reduce the impact;
2) Fit damping pads to the machine feet;
3) Optimise the platen mass distribution and carry out modal analysis;
4) Control the clamping speed in stages;
5) Detect flash thickness online;
6) Periodically calibrate platen parallelism;
7) Calculate the clamping force from the projected area;
8) Include the resonance check-up in design review.

Checklist

References

GB/T 25156-2013 Injection Moulding Machines