E42-055 · Vibration & Resonance · Multistage Centrifugal Pump DG46 · ★★★
After 3 months of running the flange seal leaks and the piping cracks
[Shaft Critical Speed] With a shaft diameter d=35mm and a span L=520mm, the first critical speed is n_c≈2950rpm; the working speed of 2980rpm is very close to it.
[Resonant Vibration] The operating point lies close to critical speed, the shaft deflection is amplified 4 times and the vibration is transmitted into the piping, loosening the flange bolts and causing leaks.
[Design Omission] The critical speed was not checked and the shaft diameter was too small.
1) Increase the shaft diameter to 42mm to move away from the critical speed;
2) Leave at least 20% margin in the critical speed check-up;
3) Add elastic hangers for piping vibration isolation;
4) Tighten the flanges with a torque wrench in a specified sequence;
5) Install online vibration monitoring;
6) Dynamically balance the impeller to G2.5;
7) Add a damping pedestal to the foundation;
8) Make the critical speed a mandatory calculation in pump design.
GB/T 5656-2008 Centrifugal Pumps — Technical Conditions