E42-207 · Vibration and Resonance · Four-Column Hydraulic Press · ★★★
During rapid-downstroke, lines shake; pressure gauge pointer swings ±1.5MPa.
[Flow Pulsation] Pump displacement pulsation rate δ=8%; superimposed on piston rod acceleration segment flow Q sudden change; line liquid column natural frequency is close. [Pressure Oscillation] Pressure waves reflect in the line; swing ±1.5MPa loosens fittings. [Design Omission] No accumulator provided; pipe clamp spacing too large.
1. Add a 10L bladder accumulator in the main oil line.
2. Reduce pipe clamp spacing from 1500mm to 800mm.
3. Replace pump with low-pulsation variable displacement pump.
4. Replace high-pressure rubber hose with hard pipe and add supports.
5. Install relief valve in system to stabilize pressure.
6. Factory hydraulic pulsation test ≤±0.5MPa.
7. Shift-point inspection of loose fittings each shift.
8. Recheck line natural frequency each quarter.
GB/T 3766-2015