E42-208 · Vibration and Resonance · 4-72 Centrifugal Fan · ★★★
Outlet noise 98dB(A) (allowable 85); housing wall vibration velocity 8mm/s.
[Blade Passing Frequency] Blade number z=10, speed n=1450rpm; passing frequency f_bp=242Hz close to housing first-order natural frequency. [Structural Radiation] Housing excited by pulsating force into resonance; vibration velocity amplified to 8mm/s. [Design Omission] Housing not modal-analyzed; wall thickness margin insufficient.
1. Increase housing wall thickness from 4mm to 6mm and add stiffeners.
2. Conduct whole-fan modal analysis to avoid f_bp.
3. Use unevenly spaced blades (z=9/11) to break up frequency.
4. Line housing interior with damping layer to reduce vibration.
5. Install flexible connections at inlet/outlet for isolation.
6. 100% noise inspection at shipment ≤85dB(A).
7. Recheck housing vibration velocity each quarter.
8. Install 4 vibration isolators on the foundation.
GB/T 2888-2008