E42-209 · Vibration and Resonance · BF Reduction Gearbox · ★★★
High-speed stage shows high-frequency whine 3000Hz; housing wall vibration velocity 7mm/s.
[Mesh Excitation] Tooth number z=25, n=2900rpm; 2.5x mesh frequency f_m=1208Hz ≈3000Hz close to housing wall natural frequency. [Housing Radiation] Thin wall forced vibration amplified; whine radiates outward. [Design Omission] Housing not modal-analyzed; uneven wall thickness.
1. Increase housing wall thickness from 8mm to 12mm.
2. Add longitudinal and transverse stiffeners to housing.
3. Gear tooth profile modification to reduce mesh impact.
4. Apply damping vibration-reduction coating to housing.
5. Locally thicken bearing housing support.
6. 100% noise spectrum inspection at shipment, no peaks.
7. Recheck housing wall vibration velocity each quarter.
8. Raise gear accuracy to grade 6.
GB/T 6404.1-2005