Knowledge Base › Structural Design Error Case Study › Large Motor Electromagnetic Force Frequency Doubling Causing Stator Core Vibration

Large Motor Electromagnetic Force Frequency Doubling Causing Stator Core Vibration

E42-210 · Vibration and Resonance · Y2-315 Three-Phase Asynchronous Motor · ★★★

Problem Description

No-load vibration velocity 6.5mm/s (allowable 2.8); frame radiates electromagnetic noise.

Root Cause

[Electromagnetic Force Wave] Uneven air gap δ deviates 0.15mm; produces 2x power frequency 100Hz radial force wave, close to frame natural frequency. [Core Vibration] Laminated core forced vibration amplified; frame vibration velocity 6.5mm/s. [Design Omission] Stator concentricity not controlled; rotor dynamic balance poor.

Corrective Solution

1. Control stator bore and rotor concentricity to ≤0.05mm.
2. Dynamically balance rotor to G2.5.
3. Add axial stiffeners to frame.
4. Raise core lamination compression density to 98%.
5. End shield bearing housing coaxiality ≤0.02mm.
6. 100% vibration inspection at shipment ≤2.8mm/s.
7. Recheck vibration velocity each quarter.
8. Switch fan to low-noise backward-curved blades.

Checklist

Reference

GB/T 10068-2020