E42-361 · Vibration and Resonance · IS80-50-200 Centrifugal Pump · ★★
IS80-50-200 centrifugal pump cavitation vibration severity 7.1mm/s exceeds 4.5 allowance; impeller pitting depth 3mm; 3 units repaired per month
[Cavitation] Suction lift 5.5m exceeds NPSHr=4m; bubble collapse excites vibration.
[Vibration] Blade passing frequency excitation severity 7.1mm/s.
[Design Omission] NPSH not calculated; inlet pipe diameter too small; safety factor 1.2.
1) Lower installation height to within 3m;
2) Enlarge inlet pipe diameter by one size;
3) Calculate NPSHa ≥ NPSHr+0.5;
4) Change impeller to anti-cavitation material;
5) Measure vibration severity each batch;
6) Add inducer;
7) Limit speed;
8) Periodic opening inspection.
GB/T 5657-2013