Knowledge Base › Structural Design Error Case Study › Centrifugal Pump Impeller Cavitation-Induced Vibration

Centrifugal Pump Impeller Cavitation-Induced Vibration

E42-361 · Vibration and Resonance · IS80-50-200 Centrifugal Pump · ★★

Problem Description

IS80-50-200 centrifugal pump cavitation vibration severity 7.1mm/s exceeds 4.5 allowance; impeller pitting depth 3mm; 3 units repaired per month

Root Cause

[Cavitation] Suction lift 5.5m exceeds NPSHr=4m; bubble collapse excites vibration.
[Vibration] Blade passing frequency excitation severity 7.1mm/s.
[Design Omission] NPSH not calculated; inlet pipe diameter too small; safety factor 1.2.

Corrective Solution

1) Lower installation height to within 3m;
2) Enlarge inlet pipe diameter by one size;
3) Calculate NPSHa ≥ NPSHr+0.5;
4) Change impeller to anti-cavitation material;
5) Measure vibration severity each batch;
6) Add inducer;
7) Limit speed;
8) Periodic opening inspection.

Checklist

Reference

GB/T 5657-2013