E42-362 · Vibration and Resonance · ZDY112 Reducer Housing · ★★

Problem Description

ZDY112 gearbox at 2900r/min housing resonates; noise 92dB; tooth surface pitting; 2 units repaired per month

Root Cause

[Modal] Housing first-order f=48Hz coincides with tooth frequency 48.3Hz; resonance.
[Pitting] Amplified vibration causes poor tooth contact.
[Design Omission] No modal analysis; uneven wall thickness; safety factor 1.2.

Corrective Solution

1) Add housing stiffeners to raise first-order to ≥60Hz;
2) Uniformize wall thickness;
3) Modal analysis each batch;
4) Detune tooth frequency by ≥20%;
5) Locally thicken bearing housing;
6) Acoustic enclosure;
7) Limit speed;
8) Periodic vibration measurement.

Checklist

Reference

JB/T 8853-2001